Wind Energy Handbook. Michael Barton Graham. Читать онлайн. Newlib. NEWLIB.NET

Автор: Michael Barton Graham
Издательство: John Wiley & Sons Limited
Серия:
Жанр произведения: Физика
Год издания: 0
isbn: 9781119451167
Скачать книгу
deviation of wind speed in across‐wind directionσwstandard deviation of wind speed in vertical directionσx1standard deviation of first mode resonant displacement, referred to blade tip for blade resonance and to nacelle for tower resonanceτtime interval; non‐dimensional time; shear stressυPoisson's ratioϕflow angle of resultant velocity W to rotor plane; velocity potential; blade azimuth (Section 8.3.11)Φ()standard normal distribution functionΦ(x, y, z, t)velocity potential due to unit sourceΦWagner (impulsive heave motion) function (Sections 4.5.3 and 4.6.2)χwake skew angle: angle between the axis of the wake of a yawed rotor and the axis of rotation of rotor; buckling strength reduction factor; fibre inclination to blade panel axisχM1weighted mass ratio defined in Section 5.8.6ψblade azimuth; angle subtended by cylindrical plate panel; stream function parameter with respect to fixed reference frame; wake amplification factor
stream function parameter with respect to frame of reference moving at same speed as wave crests and troughsψuu(r, r', n)real part of normalised cross‐spectrumΨKussner (indicial gust) functionωangular frequency (rad/s)ωddemanded generator rotational speedωinatural frequency of ith mode (rad/s)ωggenerator rotational speedωrinduction machine rotor rotational speedωsinduction machine stator field rotational speedΩrotational speed of rotor; Earth's rotational speed

      Subscripts

      aaerodynamicBbaselineccompressiveddisc; drag; designemotion due to elastic deformatione1extreme value with return period of 1 yeare50extreme value with return period of 50 yearsextextremeffibreimode ijmode jJblade JkcharacteristiclliftmmatrixMmomentmaxmaximum value of variableminminimum value of variablenvalue at end of nth timestepQgeneralised loadRvalue at tip radius, RsstructuralttensileTthrustudownwind; ultimatevlateralwverticalwwakexdeflection in along‐wind direction

      Superscripts

      orotationally sampled (applied to wind speed spectra)

      Figures C1 and C2 – coordinate systems

Schematic illustration of the coordinate system for blade loads, positions, and deflections (rotates with blade).

      Figure C1 Coordinate system for blade loads, positions, and deflections (rotates with blade).

Schematic illustration of the fixed coordinate system for hub loads and deflections, and positions with respect to hub.

      Figure C2 Fixed coordinate system for hub loads and deflections, and positions with respect to hub.

      1

      Introduction

      Windmills have been used for at least 3000 years, mainly for grinding grain or pumping water, while the wind has been the essential source of power in sailing ships for even longer. From medieval times, horizontal axis windmills were an integral part of the rural economy throughout Europe and only fell into disuse with the advent of cheap fossil‐fuelled stationary engines and then the spread of rural electrification (Musgrove 2010).

      The use of windmills (or wind turbines) to generate electricity can be traced back to the late nineteenth century with the 12 kW direct current windmill generator constructed by Charles Brush in the USA and the research undertaken by Poul la Cour in Denmark. However, for much of the twentieth century, there was little interest in using wind energy, other than for battery charging for remote dwellings; these low power systems were quickly removed once more reliable and higher power electricity supplies from the public electricity network became available. One notable development was the 1250 kW Smith–Putnam wind turbine constructed in the USA in 1941. This remarkable machine had a steel rotor 53 m in diameter, full‐span pitch control, and flapping blades to reduce loads. Although a blade spar failed catastrophically in 1945, it remained the largest wind turbine constructed for some 40 years (Putnam 1948).

      The sudden increase in the price of oil stimulated a number of substantial, government‐funded programmes of research, development, and demonstration. In the USA, this led to the construction of a series of prototype turbines starting with the 38 m diameter 200 kW Mod‐0 in 1975 and culminating in the 97.5 m diameter 3.2 MW Mod‐5 in 1987. Similar programmes were pursued in Germany with the Growian, 100 m diameter 3 MW turbine built in 1982 and in the UK with the LS‐1 60 m diameter 3 MW turbine in 1988, both of which had two blades (Hau 2010). There was considerable uncertainty as to which architecture might prove most cost‐effective, and several innovative concepts were investigated at full scale. In Canada, a 4 MW vertical axis Darrieus wind turbine was constructed, and this concept was also investigated in the 34 m diameter Sandia vertical axis test facility in the USA. In the UK, an alternative, vertical axis design using straight blades in an ‘H’ type rotor was proposed by Dr Peter Musgrove and a 500 kW prototype constructed. In 1981, the innovative Schachle‐Bendix horizontal axis 3 MW wind turbine was built and tested in the USA (Spera 1994). This used hydraulic transmission, and, as an alternative to a bearing at the top of the tower and yaw drive, the entire structure was orientated into the wind. Several prototypes used a single blade and counterweight, including the 600 kW MBB Monopteros in 1985 (Hau 2010).

      Much important scientific and engineering information was gained from these government‐funded research programmes, and the prototypes generally worked as designed. However, the problems of operating very large wind turbines, unmanned and in difficult wind climates, were often underestimated, and the reliability of the prototypes was not good. At the same time as the multi‐megawatt prototypes were being constructed, private companies, often with considerable state support, were constructing much smaller and simpler turbines for commercial sale. In particular, the financial support mechanisms in California in the mid‐1980s resulted in the installation of a very large number of quite small (around 100 kW) wind turbines of various designs. Many of these designs also suffered from various problems, but, being smaller, they were easier to repair and modify.