et al. [144] prepared highly linear and sensitive graphene/PDMS composite films with microdome structures. They found that pressure sensor made of hierarchical graphene/PDMS array with wrinkles on the surface of the microdome was more sensitive to external stimuli than sensor made of smooth-dome graphene/PDMS array. This novel type of pressure sensor exhibits a superb endurance of 10 000 cycles and a low detection limit of 1 Pa.

      2.4.3 Gas Sensor

(a) SEM image showing the surface morphology of the composite elastomers (scale bar: 10 μm); Inset photograph shows the flexibility of the film composite. (b) Schematic diagram (top) and SEM image (bottom) of the fracture surface for the composite films (scale bar: 5 μm). (c) Schematic illustration demonstrating the operation principle of the film composite. (d) The pressure sensing performance of composite film with different structures. (e) Relative resistance (R/R0) as a function of applied pressure (log–log plot) for the sensor with interlocked microdome arrays (8 wt% CNTs). Source: (a)–(e) Reproduced with permission. [149] Copyright 2014, American Chemical Society. Schematic illustration of conductive networks formed by carbonaceous filler in PLA during immersion-drying runs. (a–d) Illustrating the evolution of conductive networks in CB/PLA, CB/RF/PLA, CNTs/PLA, and CNTs/RF/PLA, respectively (the red lines and circles suggest the changes of conductive paths). Source: (a)–(d) Reproduced with permission. [154] Copyright 2015, Elsevier B.V.

      Usually, CPCs with disordered dispersion of conductive nanofillers show poor sensing repeatability, because the swelled conductive network can't perfectly recover when the materials is taken out from the vapor in most cases. To solve this problem, CPCs with segregated structures have become alternatives [156, 157], because organic vapors or liquids could more easily be permeated in the CPC by the capillary effect generated from the interfaces of polymer matrix.

      Sensor that could detect both humidity and chemical vapors with high sensitivity and low detection limit is reported by Huang et al. [155]. The obtained conductive ACNT/PU nanofiber membrane shows excellent superhydrophilicity and underwater superoleophobicity, and it is sensitive to both humidity and chemical vapors. The membrane composite can be integrated into masks to detect human respiration showing potential usage in monitoring biomarker gases from human breath (Figure 2.9d–f).

Cyclic vapor sensing behavior of the nanofiber composite with different SEBS contents to different vapors including: (a) THF, (b) toluene, and (c) heptane. Source: (a)–(c) Reproduced with permission. [116] Copyright 2018, The Royal Society of Chemistry. (d) Photos of a volunteer wearing the integrated mask, and the mask incorporated with CNC-based humidity sensor. (e) Vapor sensing behavior of the sensor to fast, normal, and deep breathing and (f) mouth and nose breathing. Source: (d)–(f) Reproduced with permission. [155] Copyright 2019, American Chemical Society.

      2.4.4 Temperature Sensor

      CPCs served as temperature sensors show many popular applications for thermal detectors, over-temperature protection devices and self-regulating heaters, etc. [158]. The temperature sensing behavior of CPCs is based on positive temperature coefficient (PTC) effect and negative temperature coefficient (NTC) effect. Conceptually, PTC and NTC of thermistors display a conspicuous increase and a succeeding gradual decrease in electrical resistance with increasing temperature, respectively [122]. It is believed that the PTC effect arises from the expansion or the melting of the matrix, which would increase the distance between conductive elements. While a flocculated structure formed at elevated temperatures, resulting in NTC effect.