and surface area. Moreover, SBSE desorption can be directly developed in a thermal desorption unit in many GC systems, so it maintains one of the main advantages derived from the use of SPME [64]. Since then, this technique has evolved and a wide variety of laboratory made coatings have been developed in order to extend the field of application of SBSE, especially to the extraction of polar compounds, as well as to improve its selectivity [64]. Up to now, few works have used SBSE for the determination of PAEs in water samples (see Table 1.1). This is the case of the work of Prieto et al. [65], who analyzed six PAEs together with sixteen polycyclic aromatic hydrocarbons (PAHs), twelve polychlorinated biphenyls (PCBs) and three nonylphenols in sea and estuarine waters, and that of Si et al. [66], who extracted fifteen PAEs from sea water. In both works, commercial PDMS-coated stir bars of 0.5- and 1-mm thickness were used, respectively. In both cases, the addition of methanol (MeOH) to the water sample (20% for 0.5-mm thickness fibers and 10% for 1-mm thickness fibers, v/v) was crucial to avoid PAEs adsorption on the glass walls and to improve the extraction efficiency, particularly for long chain PAEs. In the last work, four commercially available stir bars containing different amounts of PDMS were evaluated in terms of extraction capacity. The results showed that the stir bar containing the highest amount (150 μL vs. 50, 75, and 150 μL over carbon) provided the largest peak areas, which was consistent with the principles of the process. However, the sensitivity for the higher-molecular weight PAEs (i.e., DNOP and DEHP) was notably lower, which is probably caused by the fact that this kind of nonpolar compounds establish strong interactions with the PDMS coating which could result in an incomplete desorption and the consequent higher LODs and LOQs. The combination of SBSE with GC-MS systems using single quadrupoles operated in the SIM mode allowed obtaining high extraction efficiency as well as high sensitivity (0.1–489 ng/L) in general.

      Table 1.2 Some examples of the application of SPE for the analysis of PAEs in water samples.

PAEs Matrix (sample amount) Sample pretreatment Separation technique LOQ Recovery study Residues found Comments Reference
DMP, DEP, DIBP, DBP, DMEP, BMPP, DEEP, DNPP, DHXP, BBP, DBEP, DCHP, DEHP DNOP, and DNP River and sea waters (20 mL) dSPE using 3 mL colloidal G and vortex for 2 min, centrifugation at 3800 rpm for 5 min, and desorption with 5 mL ethyl acetate and 2 g sodium sulfate by vortex for 30 s GC-MS 5–20 μg/L 72–117% at 20 and 50 μg/L Nine river and 2 sea waters samples were analyzed and contained at least 1 PAE at levels from 2 to 78 μg/L Ethyl acetate showed higher extraction efficiency than ACN, acetone and hexane as desorption solvent [72]
DEHP Rain, lake and river waters (600 mL) dSPE using 20 mg GO-MIP and agitation for 30 min, centrifugation at 12000 rpm for 10 min, and desorption (twice) with 2.5 mL acetone by vortex for 1 min and subsequent sonication for 5 min HPLC-UV 2.82 μg/L 82-92% at 5, 50, and 500 μg/L One sample of each water were analyzed and residues were found at 0.32 ± 0.08 and 1.56 ± 0.32 μg/L in lake and river waters, respectively. DEHP was used as the template molecule. Acetone showed higher extraction efficiency than MeOH as desorption solvent [69]
DMP, DEP, DBP, BBP, DEHP, and DNOP Bottle water (200 mL) dSPE using 60 mg DMIMs and stirring for 90 min, and desorption with 5 mL dichloromethane by sonication for 15 min GC-MS 1.03–1.35 μg/L 92.4–99.0% at 25 μg/L Two samples were analyzed and residues of DEHP were found at 10.06 ± 0.84 and 11.90 ± 1.70 μg/L DEP was used as the dummy template. Dichloromethane showed higher extraction efficiency than acetone, MeOH, chloroform, ethyl acetate and hexane as desorption solvent. DMIMs-dSPE method showed higher recovery values compared with non-imprinted polymers [73]
DMP, DEP, and DBP Tap and mineral