Common Objects of the Microscope. John George Wood. Читать онлайн. Newlib. NEWLIB.NET

Автор: John George Wood
Издательство: Public Domain
Серия:
Жанр произведения: Зарубежная классика
Год издания: 0
isbn:
Скачать книгу
the bloom upon the surface would be invisible in detail without optical aid. Conversely, however, it would be rash to conclude from an examination of a portion of the surface with the microscope alone that the portion in view was a sample of the whole surface. The more the surface is magnified, the less are the details grasped as a whole, and for this reason the observer is strongly recommended to make out all that he can of an object with a simple magnifier before resorting to the microscope.

      For general purposes, the intending observer cannot do better than supply himself with a common pocket-magnifier, with one, two, or three lenses, preferably the last, as although the absolute performance is not so accurate, the very considerable range of power available by using the lenses singly, or in various combinations, is of great advantage. Such a magnifier may be obtained from Baker for about three-and-sixpence, or, with the addition of a powerful Coddington lens (Fig. 5) in the same mount, for nine shillings more. Aplanatic lenses, such as the one shown in section in Fig. 6, with a much flatter field of vision, but of one power only each, cost about fifteen shillings, and a simple stand, which adapts them for dissecting purposes, may be obtained of the same maker for half a crown, or may easily be extemporised from a cork sliding stiffly on an iron rod set in a heavy foot, the cork carrying a loop of wire terminating in a ring which carries the lens.

      Fig. 5.

      Fig. 6.

      So much may suffice for the simple microscope. We pass on now to the consideration of the instrument which forms the subject of the present work, an instrument which, whilst moderate in price, is yet capable of doing a large amount of useful and valuable work in the hands of a careful owner, and of affording him a vast amount of pleasure and recreation, even if these be his only objects in the purchase, though it is difficult to understand that, an insight being once attained into the revelations effected by the instrument, without a desire being excited in any intelligent mind to pursue the subject as a study as well as a delightful relaxation. The microscope described, and adopted as his text by the author of this work, is still made, and has shared to a very considerable extent in the general improvement of optical apparatus which has taken place during the last thirty years. It is to be obtained from Baker, 244 High Holborn, and is provided with most of the apparatus which will be found indispensable by the beginner, costing, with a case in which to keep it, the modest sum of three guineas.

      Fig. 7.

      If this instrument represent the limit of the purchaser’s power of purse, he may very well make it answer his purpose for a considerable time. The same instrument, however, with separate objectives of good quality, together with a bull’s-eye condenser (an almost indispensable adjunct), a plane mirror in addition to a concave one, and a simple but efficient form of substage condenser, may be obtained for £5, 12s. 6d., and the extra outlay will be well repaid by the advantage in working which is gained by the possession of the additional apparatus.

      Fig. 8.

      A still better stand, and one which is good enough for almost any class of work, is that shown in Fig. 8, which is known as the “Portable” microscope. In this instrument the body is made up of two tubes, so that the length may be varied at will, and this gives a very considerable range of magnification without changing the object-glass, a great convenience in practice; whilst the legs fold up for convenience of carriage, so that the whole instrument, with all necessary appliances, may be readily packed in a corner of a portmanteau for transport to the country or seaside.

      The objectives supplied with the simplest form of microscope above referred to are combinations of three powers in one, and the power is varied by using one, two, or three of these in combination. This form of objective is very good, as far as it goes, though it is impossible to correct such a combination with the accuracy which is possible in manufacturing one of a fixed focal length.

      Perhaps the best thing for the beginner to do would be to purchase the combination first, and, later on, to dispose of it and buy separate objectives of, say, one-inch, half-inch, and quarter-inch focal lengths. It may be explained here, that when a lens is spoken of as having a certain focal length, it is meant that the magnification obtained by its use is the same, at a distance of ten inches from the eye, as would be obtained by using a simple sphere of glass of the same focal length at the same distance. This, of course, is simply a matter of theory, for such lenses are never used actually.

      Fig. 9.

      Of accessory apparatus, we may mention first the stage forceps (Fig. 9, a). These are made to fit into a hole upon the stage, so as to be capable of being turned about in any direction, with an object in their grasp, and for some purposes, especially such as the examination of a thin object, say the edge of a leaf, they are extremely useful.

      Fig. 10.

      The live box, in which drops of water or portions of water-plants, or the like, may be examined, will be found of great service. By adjustment of the cap upon the cylinder, with proper attention to the thickness of the cover-glass in the cap, any required amount of pressure, from that merely sufficient to fix a restless object to an amount sufficient to crush a resistent tissue, may easily be applied, whilst the result of the operation is watched through the microscope. This proceeding is greatly facilitated if the cap of the live-box be slotted spirally, with a stud on the cylinder, so that a half-turn of the cap brings the glasses into contact. By this means the pressure may be adjusted with the greatest nicety.

      In examining delicate objects, such as large infusoria, which invariably commit suicide when pressure is applied, a good plan is to restrict their movements by placing a few threads of cotton-wool, well pulled out, in the live-box with the drop of water.

      A variety of instruments has been invented for the same purpose, of which Beck’s parallel compressorium may be mentioned as the most efficient, though it is somewhat complicated, and consequently expensive, costing about twenty-five shillings.

      A few glass slips and cover-glasses will also be required. The latter had better be those known as “No. 2,” since the beginner will find it almost impossible to clean the thinner ones satisfactorily without a large percentage of fractures. The safest way is to boil the thin glass circles in dilute nitric acid (half acid, half water) for a few minutes, wash well in several waters, first tap-water and then distilled, and finally to place the covers in methylated spirit. When required for use, the spirit may be burnt off by applying a light, the cover-glass, held in a pair of forceps, being in no way injured by the process.

      In addition to the glass slides, the observer will find it advisable to be provided with a few glass troughs, of various thicknesses, in which portions of water-plants, having organisms attached to them, may be examined. Confined in the live-box, many of the organisms ordinarily found under such circumstances can rarely be induced to unfold their beauties, whilst in the comparative freedom of the trough they do so readily. The troughs may be purchased, or may be made of any desired shape or size by cutting strips of glass of a thickness corresponding to the depth desired, cementing these to a glass slide somewhat larger than the ordinary one, and cementing over the frame so formed a piece of thin glass, No. 3; the best material to use as cement being marine glue of the best quality, or, failing this, Prout’s elastic glue, which is much cheaper, but also less satisfactory. The glass surface must be made, in either case, sufficiently hot to ensure thorough adhesion of the cement, as the use of any solvent entails long waiting, and considerable risk of poisoning the organisms. A useful practical hint in the use of these troughs is that the corners, at the top, should be greased slightly, otherwise the water finds its way out by capillary attraction, to the detriment of the stage of the microscope.

      Of optical accessories,