acid and coated with polycaprolate (Tan et al. 2003). Polycaprolate is a copolymer of glycolide and ε‐caprolactone. Polyglycolic acid is rapidly absorbed and quickly loses tensile strength. Fourteen days following implantation, polyglycolic acid only has 20% of its initial tensile strength and is completely absorbed in 60 days.

      Polyglytone 6211

      Polyglytone 6211 is a newer monofilament absorbable suture composed of synthetic polyester of glycolide, caprolactone, trimethylene carbonate, and lactide (Pineros‐Fernandez et al. 2004). It provides short‐term tensile strength combined with the benefits of rapid absorption losing 70–80% of its tensile strength in 10 days and being completely absorbed in 56 days (van Heerden 2005).

      Lactomer™

      Lactomer is a braided suture composed of polymers of glycolide and lactide. It is coated with ε‐caprolactone glycolide and calcium stearoyl lactylate to improve handling properties. Lactomer retains 80% of its tensile strength at 2 weeks and 30% at 3 weeks with complete absorption between 56 and 70 days.

      Nonabsorbable suture materials do not undergo significant degradation after implantation. These sutures are used where extended wound support is required or in areas where suture removal is expected (skin closure). Nonabsorbable sutures, like absorbable sutures, are composed of natural or synthetic fibers. Natural fibers tend to invoke significant inflammatory reactions; thus, there may be a preference for synthetic nonabsorbable sutures depending on the application. Nonabsorbable suture materials commonly used in veterinary surgery include silk, nylon (Ethilon™, Ethicon Inc., Cincinnati, OH; Monosof™, Covidien, Medtronics, Minneapolis, MN; Nurolon™, Ethicon Inc., Cincinnati, OH; Supramid™, S. Jackson, Inc., Alexandria, VA), polypropylene (Prolene™, Ethicon Inc., Cincinnati, OH; Surgipro™, Covidien, Medtronics, Minneapolis, MN), and stainless steel.

      Silk

      Silk is the most commonly used organic nonabsorbable suture material (Fossum 2002; Roush 2003; Tan et al. 2003). It is a braided suture with excellent handling properties and knot security. Silk loses a significant amount of its tensile strength after extended implantation but is considered nonabsorbable because the material remains in the tissues for a significant amount of time. There is a 30% loss of tensile strength at 14 days and 50% loss at 1 year. Time for complete absorption is greater than 2 years. Silk leads to significant reaction in tissues, and the presence of silk suture can reduce the number of bacteria needed to induce an infection from 106 to 103 (Fossum 2002).

      Nylon

      Nylon is a synthetic nonabsorbable suture that is available as a monofilament or braided suture (Ratner et al. 1994; Fossum 2002; Roush 2003; Tan et al. 2003). Nylon maintains a high level of elasticity, but undergoes little to no plastic deformation prior to breakage and monofilament nylon is relatively stiff. Overall, it has moderate handling characteristics and knot security with minimal tissue response. Multifilament nylon has improved handling characteristics, but increased capillarity. Although it is nonabsorbable, monofilament nylon loses 30% of its tensile strength after two years and braided nylon loses 75–100% of its tensile strength at 6 months.

      Polypropylene

      Polypropylene is a synthetic monofilament nonabsorbable suture material composed of stereoisomers of polypropylene (Tan et al. 2003). It has the greatest strength of the synthetic nonabsorbable sutures and has no appreciable loss of tensile strength after implantation (Tan et al. 2003); however, evaluation of polypropylene sutures over 2 and 5 year periods show some fragmentation (Postlethwait 1970, 1979). Polypropylene has a very smooth surface and has minimal tissue drag, but this property can also lead to slippage and poor knot security (Ratner et al. 1994). Other disadvantages are the handling properties and memory.

      Stainless Steel

      Stainless steel is an alloy of chromium, nickel, and molybdenum and is available as a monofilament or braided suture (Fossum 2002; Tan et al. 2003). It is biologically inert and has the greatest strength of all suture materials. Stainless steel sutures are extremely stiff and tend to cut through tissues or cause necrosis when there is tissue movement over buried knots.

      Barbed sutures have been used for a variety of human surgical procedures. The suture barbs are arranged in order to prevent pull out and eliminate the need for a knot at the end of the suture line. There are a few studies in the veterinary literature regarding barbed sutures, but their use is not widespread.

      Triclosan is a broad spectrum antibacterial agent that has been added to many suture materials. Triclosan‐coated sutures inhibit growth of common skin flora and some methicillin‐resistant strains of Staphylococcus in vitro. Triclosan‐coated sutures are available for use in veterinary surgery; however, their efficacy in reducing surgical site infections is unclear and current studies have varying results (Rothenburger et al. 2002; Storch et al. 2004; Etter et al. 2013). Triclosan‐coated sutures were studied in ball pythons and no difference was seen in inflammatory response or surgical site infections (McFadden et al. 2011).

      In addition to triclosan, chlorhexidine‐coated sutures are also available. Chlorhexidine diacetate is a biguanide antiseptic that exhibits a broad range of antimicrobial activity intended to inhibit the growth of Gram‐negative and Gram‐positive bacteria. Studies assessing the effectiveness of chlorhexidine are limited (Onesti et al. 2018), and at the time of this chapter preparation, no veterinary specific studies have been published.

      Compared with other tissues, the bladder heals very quickly and regains normal tensile strength in 14–21 days (Cornell 2012). When choosing a suture material to use for bladder repair, Monocryl, Biosyn, Dexon, or Vicryl may be recommended based on the amount of time these suture materials retain sufficient tensile strength, thus allowing the bladder tissue to heal. Longer‐lasting absorbable sutures such as Maxon or PDS are probably not appropriate for bladder surgery unless delayed healing is anticipated. Nonabsorbable sutures may promote calculus formation. Conversely, sutures that are absorbed very rapidly (e.g. Caprosyn, Vicryl Rapide) probably do not retain sufficient tensile strength long enough and may increase the risk of dehiscence.

      The gastrointestinal tract also heals at a relatively rapid rate, with the strength of the repair site approximating the original tissue strength in 10–17 days for the small intestine and up to 30 days for the large intestine (Durdey and Bucknall 1984; Hedlund 2002). The maturation phase in gastrointestinal tract healing occurs between 10 and 180 days after surgery. Polydioxanone, Monocryl, Biosyn, or Maxon provide sufficient tissue support for the gastrointestinal tract to allow for adequate healing.

      Healing time for fascia is longer than for the gastrointestinal tract or urinary tract; therefore, fascia requires prolonged tissue support. Twenty days after surgery, the body wall has only regained 20% of its original tensile strength (Cornell 2012). Because fascia has a slower healing time, suture materials that will provide longer support of the tissues (e.g. PDS, Maxon) are recommended. Tissues such as tendons can take